Technical information
Primary Causes of TEM Malfunction
During Assembly
At customer assembly
In action
Shock / Impact
Dropping of a TEM or excessive contact forces with other assembly components.
Overheating
Inadequate heat removal on the hot side of the TEM due to high thermal resistance at the heat sink.
Internal Corrosion
Generation of internal condensation (in an unprotected module) during cooling below the dewpoint resulting in internal corrosion of the TEM elements
Life
Cycling Induced Damage